DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-770ETH-PT (Control LAN Ethernet)
9
1125 ABORT Ethernet link not in service.
1. Verify whether Ethernet link is in service (status port UUCSSpp or
status link n).
2. If the Ethernet link is not in service, release the link (release link n or
release port UUCSSpp).
3. Repeat the test.
1959 ABORT Downlink message error.
1. Retry the command at 1-minute intervals, up to 3 times.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2100 ABORT Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2500 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
FAIL Link integrity lost due to problem with attachment of Ethernet cable to the
port.
1. Repeat the test.
2. If the test fails, verify that the cable properly is secured to Ethernet port
and to the bus.
3. Verify the CLAN circuit pack link integrity LED is glowing.
4. Retry the test.
5. If problem persists, refer to Ethernet Local Looparound Test (#1278)
repair procedures.
PASS The Ethernet Link Integrity Test (#1282) detects good connections.
Table 9-299. TEST #1282 Link Integrity Inquiry Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page