DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-778ETR-PT (Enhanced Tone Receiver Port)
9
Tone Detector Audit/Update Test (#43)
A Digital Signal Processor sanity audit is performed on the ETR-PT.
Table 9-303. TEST #43 Tone Detector Audit/Update Test
Error
Code Test Result Description/ Recommendation
none ABORT The system could not allocate all the resources needed for this test.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page