DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-286AUDIX-PT (AUDIX Port)
9
AUDIX-PT (AUDIX Port)
The AUDIX-PT maintenance object represents a port on a TN566/TN2169
DEFINITY AUDIX circuit pack operating in digital-p ort (DP) mode. For
circ uit-p ack -level prob lems (AUDIX- BD), s ee “XXX- BD (Com mon Por t Circ uit
Pack) ”.
The maintenance strategy for ports o n the TN566 operating in control-link mode
is described in ADX16A-PT.
MO Name (in
Alarm Log) Alarm
Level Initial Command to Run1
1.
UU
is the universal cabinet number (1 for PPN, 2 - 44 for EPNs).
C
is the carrier
designat ion (A, B, C, D, o r E).
SS
is the number of the slot in which the circuit pack
resides (01 to 21).
pp
is the two digit port number (01, 02, ...).
Full Name of
MO
AUDIX-PT MINOR test port UUCSSpp l AUDIX Port
AUDIX-PT WARNING test port UUCSSpp sh AUDIX Port