DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-714DUP-CHL (Duplication Interface)

9
Duplication Channel Test (#874)

This test verifies the correct transmission of a messag e sent from the active SPE

to the stand by SPE v ia the Dupl ica tion I nterf ace c irc uit p ack m ailb ox

1420 ABORT The state-of-health of the active SPE is partially functional.
1. Use the display alarms comma nd se lecti ng th e SPE cate gory to
determine which alarms have caused the active SPE to have a lower
state-of-health. Problems causing MAJOR alarms for MEM-BD, PKT-INT,
SYSAM, H-ADAPTR, and SW-CTL should be repaired first.
2. If this abort continues to occur, the standby SPE may not have initialized
properly. Use the lock-and -power-down proc edure descr ibed in Chapter 5
to power down and power up the standby SPE, but don’t replace any
circuit pac ks. Try this test again.
2000 FAIL This test did not run because communication with the standby timed out while
waiting for a reply to a maintenance message instructing it to lower it’s
state-of-health.
1. Replace Duplication Interface comp onents starting with the standby
Duplication Interface circuit pack. Use SPE Duplication Channel
Component Replacement procedures at the end of this section.
2334 ABORT The hardware mailbox in the standby Duplication Interface circuit pack is not
ready to receive messag es.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If this abort continues to occur, the standby SPE may not have initialized
properly. Use the lock-and -power-down proc edure descr ibed in Chapter 5
to power down and power up the standby SPE, but do not replace any
circuit packs.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The standby state-of-health was lowered but no interrupt was received after the
test had instructed the standby SPE to lower its state of health.
1. Replace Duplication Interface comp onents starting with the standby
Duplication Interface circuit pack. Use SPE Duplication Channel
Component Replacement procedures at the end of this DUP-CHL section.
PASS The test successfully received the lowered state-of-health interrupt from the
standby Dupl ication Interface c ircuit pac k.
Table 9-276. TEST #873 State-Of-Health Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page