DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-532DIOD-TRK (DIOD Trunk)
9
Error Log Entries and Test to Clear Values
Notes:
a. These are in-line errors that have no specific test as sociated with them.
Refer to the following table for an explanation a nd appropriate action.
b. This is a software audit error and does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate associated
errors.
c. Aux data 57376No loop c urrent on incoming c all
Aux data 57424No loop current on outgoing call
These errors cause the Dial Tone Test (#0) to run and are only considered
a problem if the Dial Tone Test fails (in which case Error Type 1537 also
appears). In this case, the trun k may be put in ‘‘Ready-for-Service’’ state
(shown as ‘‘disconnected ’’ by status command) , which allows only
incoming calls. Run the Dial Tone Test (#0) and follow its procedures.
Table 9-217. DIOD Trunk Error Log Entries
Error Type Aux
Data Associated Test Alarm Level On/Off
Board Test to Clear
Valu e
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test port sh
15 (b) any Port Audit Update Test (#36)
18 0 Busyout trunk
grp/mbr
WARNING release trunk
769 (a) 57392 None MAJ/MIN/WRN2
2. Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command. If the Minor alarm is not downgraded by the set-options values, the Minor alarm is
upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
ON
1537 Dial Tone Test (#0) MAJ/MIN/WRN2ON test port long r 2
1793 Looparound and
Conference Test (#33) MAJ/MIN/WRN2ON test port long r 3
2049 NPE Cross Talk Test (#6) MAJ/MIN/WRN2ON test port long r 3
2561 (a,d) 57345 None
2817 (a,e) 57393 None
3073 (a,c) 57376 None
3073 (a,c) 57424 None
3585 (a,c) 57424 None