DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1379SN-CONF (Switch Node Configuration)
9
used for the boards to send uplink messages to the SPE and gives a sequen ce
of boards for the message to g et routed through so that the message ends up at
the SPE. If the SNI and SNC boards do not have processor routes, they will not
be able to send any in-line errors to the SPE.
When each individual b oard receives the processor routes, it sends a board
insertion message uplink and software inserts that board if it has no t already
been inserted. Each board is sent either one or two processor routes dep ending
on the configuration.
The test led or list config car rier command can be used to see whether boards
are inserted.
The processor route test is run as part of the long test sequence for SNC boards.
Table 9-548. TEST #760 Processor Route Audit Test
Error
Code Test
Result Description/ Recommendation
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2300 ABORT The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2301 ABORT The software timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2306 ABORT None of the circuit packs in this switch node carrier are responding to the
processor route messages sent by software.
1. Run the test led switch-node for the switch node that this switch node
carrier resides in to verify whether the LEDs on any of the boards light.
2. If none of the LEDs light for the boards in this carrier, fix any problems
associated with the connectivity of this carrier to the SPE. Use list
fiber-link to determine the fiber connections to this carrier. Check the
LEDs on all SNIs and EIs and fix any fiber problems. Enter display errors
and follow the associated repair procedures for any EXP-INTF error entries
associated with the PPN. Also, follow the associated repair procedures for
any SYNC, SNI-BD, SNC-BD, FIBER-LK, or SNI-PEER error entries.
2500 ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum of 3 times.
Continued on next page