9-58ANL-16-L (16-Port Analog Line)
9
Table 9-25. TEST #161 Looparound Test
Error
Code Test
Result Description/Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the station
extension.
2. Use the status station command to d etermine the service state of t he
port. If the port is in use, wait until the port is idle.
3. Retry the command at 1-minute intervals for a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, retry
the command at 1-minute intervals for a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present or some tone
detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals for a
maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted.
1. Use the display port UUCSSpp command to determine the station
extension. Use the status station command to determine the service
state of the port. If the port is in use, wait until the port is idle.
2. Retry the command at 1-minute intervals for a maximum of 5 times.
1005 ABORT This test is not run on ports administered as External Alert, Announcement
or combined modem pool ports. This error can be ig nored.
1018 ABORT The test has been disabled by administration. The default for the Test?
field on the station form is y. Determine why this field has been set to ā€œnā€ on
this station (this may be due t o the ringing appl ic ation Test #48, which can
be customer or terminal disturbing).
1. To enable the test for the particular analog station being tested, enter
change station extension and set the Test? field on the station to y.
Continued on next page