DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-82ANL-LINE, ANL-NE-L (8-Port Analog Line)
9
Any FAIL This test can fail due to on-board or off-board problems. Off-board
problems of concern include EXP-PN and EXP-INTF faults, TDM-BUS
faults, and faults associated with the tone detectors/tone generators. Clear
all off-board problems before replacing the board. Keep in mind that a
TDM-BUS problem is usually the result of a faulty board connected to the
backplane or bent pins on the backp lane.
1. Res olve EXP-PN or EXP-INTF e rrors.
2. Resolve TDM-BUS errors.
3. Resolve TONE-BD or TONE-PT errors.
4. Test the board when the faults from steps 1, 2, and 3 are cleared.
Replace the board only if the test fails.
PASS The port is correctly using its allocated time slots. User-reported troubles
on this port should b e investigated b y using other port t ests, by examining
station wiring, by examining the station, and by ensuring that the terminal
is correctly translated as off-premises or on-premises.
NOTE:
This test always passes for circuit packs TN712 prior to Vintage 14
and TN742 prior to Vintage 6.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could
be due to incorre ct translations, no board is inserted, an incorre ct board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-es tablish the
linkage between the internal ID and the port. If this is not the case,
dispatch to check to ensure that there is a valid board inserted.