DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-839EXP-INTF (Expansion Interface Circuit Pack)
9
5016
5017
5018
5019
5032
5033
5048
5064
5080
5096
5112
FAIL Initialization failure: the EI circuit pack reset successfully and restarted
execution, but the EI circuit pack detected communication errors during
hardware initialization. The nature of the failure may prevent the EI circuit pack
from communicating with its neighbor EI circuit pack on the op posite end of the
fiber. The fault itself may be either on the EI circuit pack or on the lightwave
transceiver.
1. If all other tests on this EI circuit pack are passing and no other errors have
been logged against this circuit p ack, replacement of the lightwave
transceiver or the circuit pack are recommended, but not critic al.
2. If all other tests on this EI circuit pack are not passing or other errors have
been logged against this circuit p ack, replace the lightwave transceiver
and/or the EI circuit p ack.
PASS The EI was successfully reset, and it did restart execution. Also, it passed all its
initialization tests and detected a lightwave transceiver. Remove the EI circuit
pack from the busyout state by using the release board PCSS command.
1. Execute test board PCSS short command. Refer to errors for each test.
0NO
BOARD No board was detected by the test.
1. Resolve either wrong board (Error 125) or no board (Error 131) issues.
2. Check that the board is properly translated and inserted . If so, check for
hyperactivity (Error 1538). If hyperactive, use the reset board UUCSS
command.
3. Run the test again. If it fails, the ID chip on board may be bad. Replace the
board and retest.
Table 9-316. TEST #224 Expansion Interface Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page