DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-543DISK (MSS Disk Circuit Pack)

9

4. Verify that the files on all storage devices are c onsistent by issuing

the test stored-data command.

Error Log Entries and Test to Clear Values

The

Servic e Stat e

field in the Alarm Log refers to the ac cessibility of the devic e.

IN (in service) means that users can ac cess the device and all maintenance tests

Table 9-223. DISK Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
1 (a) any Disk Reset (#809) MINOR OFF reset disk a|b1
1. In a system with simplex SPE, the carrier need not be specified. With duplicated SPEs, carrier a or b
must be specified.
18 (b) 0 Busyout Disk (#817) WARNING OFF release disk a|b1
250 (c) 0 Reset Disk (#894) WARNING OFF reset disk a|b1
257 (d) any Disk Looparound (#814) WARNING OFF test disk a|b1 sh r 2
258 (e) any Disk Looparound (#814) WARNING OFF test disk a|b1 sh r 2
513 (f) any Disk Diagnostics (#813) MINOR ON test disk a|b1 sh r 2
526 (g) 0 Busyout Host-adapter WARNING OFF rel host-ad a|b1
528 (h) 0 WARNING OFF
529 (i) 0 WARNING OFF reset disk a|b1
769 (j) any Disk Looparound (#814) MINOR ON test disk a|b1 sh r 2
1025 (k) any Disk Write-Read (#810) MINOR OFF test disk a|b1 l r 2
1281 (l) any Disk Diagnostics (#813) MINOR ON test disk a|b1 sh r 2
1793 (m) any Disk Looparound (#814) MINOR OFF test disk a|b1 sh r 2
2049 (n) any Disk Looparound (#814) MINOR OFF test disk a|b1 sh r 2
2305 (o) any Disk Status (#815) MINOR ON test disk a|b1 sh r 1
2306 (p) 5504 Disk Frmwr Counters
(#812) MINOR ON test disk a|b 1 sh
2561 (q) any Disk Write-Read (#810) MINOR OFF test disk a|b1 l r 2
2817 (r) any Disk Status (#815) WARNING ON test disk a|b1 sh r 2
3073 (s) any In-line MINOR ON test disk a|b1 l r 2
3329 (t) any Disk Audit (#811) MINOR OFF test disk a|b1 sh r 2
3841 (u) 2
2. If error type 1 with aux data of 123 is present, this field will indicate the cause of the out-of-service
condition. See the

MSS Error Actions

table at the end of the section on TAPE
Miscellaneous MINOR OFF test disk a|b1 l r 1
Continued on next page