DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-3Common Input Parameters
8
port circuit 6 on the c ircuit pack in c abinet 5, carrier C, slot 6. The list and
display commands are useful in relating MO locations to information such as PN
number, extension, link numbers, and so forth. Table 8-2 contains information
about the less-common com mand parameters.
Table 8-2. Less-Common Test Command Parameters
Parameter Range Default Meaning
PN# One or two-digit port network nu mber. EPN cabinets
may contain one or two port networks. Use list
cabinet to find which port networks are in each
cabinet.
print This command executes immed iately (if resources
are available) and sends o utput both to the screen
and to a printer connec ted to the terminal where the
command was entered. This op tion is available for
display, list and status commands.
schedule A scheduling form is displayed whic h allows you to
specify a start time for the c ommand. The command
is placed in the q ueue and, when executed , sends
the output to the system printer. The schedule
option is available for display, list and test
commands. When used with display alarms or
errors, a full report is generated . The usual selection
form for error and alarm reports is suppressed so
that it will not interfere with the command’s e xecution
when it is issued from the queue.
You can see what commands are c urrently queued
with the list command-queue command. A qu eued
command can b e canceled with remove
command-queue job#. This option requires that the
system printer be adminis tered on page 4 of the
Feature-Related System Parameters form.
group# 1-666 One to three-digit trunk grou p number; used to
address trunk maintenance objects.
group#/
member# 1-255 Group number followed by a slash and the one to
three-digit member numb er of an individual trunk;
used to address trunk maint enance objects.
Continued on next page