Maintenance Object Repair Procedures
9-1833UDS1-BD (UDS1 Interface Circuit Pack)
9
1. Make sure all conditions for ad ministration are met and that a
functioning UDS1 circuit p ack is inserted in the c orrect slot, or
2. Completely remove the UDS1-BD from the system using the
following steps:
a. Remove any administered DS1 trunks, access end points or
PRI endpoints associated with the c ircuit pack from their
trunk groups.
b. Execute the remove ds1 UUCSS and change circuit pack
UUCSS commands.
If all the administration condi tions are met for this circuit pac k and the red
LED is still on, follow the instructions for
LED Alarms with Error Type 1
in
Chapter 7.
b. The UDS1 Interface circuit pac k has been busied out by a busyout board
UUCSS command.
c. The UDS1-BD circuit pack is not c ompletely administered . To be fully
administered, the UDS1 circuit p ack must:
1. Have an entry in the circuit p lan via the change circuit pack
command,
2. Be administered via the add ds1 UUCSS c ommand, and
3. Be physically inserted into the correct slot.
A DS1 (UDS1-BD and DS1-BD) differs from most circuit pac ks in that
inserting the circuit p ack into the switch is not e nough to make the board
usable. It must also be admin istered with the add ds1 command.
d. No Aux Data: A wrong circuit p ack is inserted in the slot wh ere this circuit
pack is logic ally administered. To resolve this problem, either remove the
wrong circuit pac k and insert the logic ally administered circ uit pack OR
use the change circuit-pack command to read minister this slot to match
the circuit pac k inserted.
Aux Data 3: The 24/32-channel option jump er setting on the circuit p ack
does not match the option set on the DS1 circ uit pack administrati on form.
The circuit pack must b e physically removed to see the setting of the
jumper.
e. This error is associated with the Common Port Circuit Pack Maintenanc e
Test. Refe r to XXX-B D (Co mmon Po rt Cir cui t Pack ) Main tena nce
documentation for details.
f. The UDS1 Interface circuit pac k has detected a transient hardware
problem. The value in the Aux Data field indicates the type of hard ware
problem.
4352 External RAM failure
4353 Internal RAM failure
4355 Internal ROM failure