DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-299BRI-BD/LGATE-BD (ISDN-BRI Line Circuit Pack)
9
Notes:
a. This error indicates the circuit p ack totally stopped functioning or it was
physically removed from the system.
NOTE:
The alarm is logged ap proximately 11 minutes after the circuit p ack
has been removed and/or SAKI Sanity Test (#53) fails.
If the circuit pac k is not in the system, insert a circuit p ack (in the same
slot as the error indicates) to resolve this error. Or, if the c ircuit pack is in
the system and the red LED is on, then follow the instruc tions for ‘‘Red
(alarm)’’ in Chapter 7, ‘‘LED Interpretation’’.
b. This circuit pack h as been busied out via the busyout board UUCSS
command.
c. Port(s) has(have) been administered on this circuit pac k but the circuit
pack is not physic ally present.
d. This error indicates transient c ommunication problems b etween the switch
and this circuit pac k. Execute the test board UUCSS command and refer
to the repair procedu res for the Control Channel Loop Around Test (#52).
1793 (j) 46080 MINOR ON
1794 (j) 46094 MINOR ON
1795 (j) 46085 MINOR ON
2306 (j) LANBIC Receive
Parity Error Counter
Test (#595)
3330 (k) 46083 MINOR OFF
3840 (l) 4096
to
4101
3843 (m) 46097
3999 (n) Any None
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test d escription and follow the re commended proc edures.
Table 9-136. BRI-BD Error Log Entries — Continued
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
Continued on next page