DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-708DUP-CHL (Duplication Interface)
9
Table 9-274. TEST #871 FIFO Full Interrupt Test
Error
Code Test
Result Description/ Recommendation
1321 ABORT The faceplate switches on the Duplication Interface circuit pac ks are not set to
auto.
1. If the switches are locked because you are using a replacement
procedure, continue with this procedure to the step that directs you to
unlock the active SPE by moving both switches to auto. The next step
using the test duplication-interface long clear should not abort with this
error code.
2. If the switches a re locked and a rep lacement proced ure is not being used ,
start with step 6 of the SPE Duplication Channel Component Replacement
procedure for the standby Duplication Interface Circ uit pack at the end of
this DUP-CHL section to avoid an undesired interchange when unlocking
the active SPE.
3. If this same abort is received with both switches in auto, Replace
Duplication Interface components starting with the standby Dup lic ation
Interface circuit pack. Use SPE Duplication Channel Component
Replacement procedures at the end of this DUP-CHL section. In addition
to looking for failures, also check for the absence of this 1321 abort code
when testing after the procedure directs setting the switches to auto after a
component replacement.
1325 ABORT Memory shadowing is inhibited from the standby SPE.
1. Shadowing may not be turned on yet, so wait 5 minutes and run the test
again.
2. Rerun the test; if the same 1325 abort occurs again, use the display
alarms command and selec t Category spe. If any maintenance objects
other than DUPINT or DUP-CHL have MAJOR alarms, fix these problems.
Problems causing MAJOR alarms for MEM-BD, PKT-INT, SYSAM,
H-ADAPTR, and SW-CTL should be repaired first.
3. Rerun the test; if the same 1325 ab ort occurs ag ain, look for other DUPINT
or DUP-CHL test failures by using the busyout spe-standby if not already
busied out and the test duplication-interface long clear commands. Fix
these problems according to the service doc umentation for these packs.
4. If this 1325 abort continues to occur, the standby SPE may not have
initialized properly. Use the lock-and-power-down procedure desc ribed in
Chapter 5 to power down and power up the standb y SPE, but don’t
replace any circuit packs.
1411 ABORT This test did not run because the standby Duplication Interface c ircuit pack
cannot be detected as b eing plugged in by the software.
1. If this abort continues to occur, the standby SPE may not have initialized
properly. Use the lock-and-power-down procedure desc ribed in Chapter 5
to power down and power up the standby SPE, but don’t replace any
circuit packs.
Continued on next page