DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-296AUX-TRK (Auxiliary Trunk)
9
Table 9-135. TEST #114 Diagnostic TestAuxiliary Trunk Test
Error
Code Test
Result Description/Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member num ber of the port. Use the statu s trunk command to
determine the service state of the port. If the port is in use, wait until the
port is idle.
2. Retry the command at 1-minute intervals for a maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted.
1. Use the display port UUCSSpp command to determine the trunk
group/member num ber of the port. Use the statu s trunk command to
determine the service state of the port. If the port is in use, wait until the
port is idle.
2. Retry the command at 1-minute intervals for a maximum of 5 times.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
FAIL This test failed to detect ground.
1. Try the test once more.
2. If the test fails again, replace the circuit pack.
PASS This test passed. Ground w as detected.
Continued on next page