DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-495DID-TRK (Direct Inward Dial Trunk)
9
1006 ABORT The port is out of service, perhaps busied out.
1. Use display port UUCSSpp to determine the trunk group/member
number of the port. Use status trunk to determine the servic e state of
the port. If the port is out of service, wait until the port is in service and
idle before testing.
2. If the port status is in service and idle, then retry the command at
1-minute intervals a maximum of 5 times.
2100 ABORT Could not allocate the necessary system resources to run the test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS This test passed. Translation informat ion was successfully upd ated on the
circuit pack.
1. If signaling troubles are reported (Error Types 1, 257, or 513), verify
translation for this port.
2. Refer problem to the CO.
0NO
BOARD The test could not relate the internal ID to the port.
1. Check to ensure that the board translations are correct. Translate the
board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-estab lish the linkage
between the internal ID and the port.
Table 9-203. TEST #36 Port Audit Update Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page