Maintenance Architecture
1-8How to use the Maintenance book
1
8. Note the Error Type (Err Type field) value (1547) and the Aux Data
value if present.
9. Find the DID-TRK MO in the Maintenance Object c hapter of the
appropriate maintenanc e book.
10. In the first table look up the initial c ommand to run in the MAJOR row of the
table (Step 4 indicated that a DID trunk in slot 10, carrier C has a MAJOR
alarm).
11. Type test port 01C1008 long and press Ente r.
“01C1008” is the add ress of the alarmed port (see Screen 1-2 and Screen
1-3)
12. While the port test is running, look up the Error Type (1537 from Screen
1-3) in the DID Trunk Error Log Entries table (example below).
13. Since the Test to Clear Value (test port 01C1008 sh r 1) is very similar to the
initial test you ran in Step 11, wait for the results of the port test.
14. When the port test finishes, the following d isplay appears (Screen 1-4):
MO Name (in
Alarm Log) Alarm Level Initial Command to Run1
1.
UU
is the universal cabinet number (1 for PPN, 2 - 44 for EPNs),
C
is the carrier designation (A, B,
C, D, or E),
SS
is the number of the slot in whic h the circuit pac k resides (01 to 21), and
pp
is the
two digit port number (01, 02, ...).
Full Name of MO
DID-TRK MAJOR2
2. A MAJOR alarm on a truk indicates that alarms on these trunks are downgraded by the set options
command and that a t least 75% of the trunks in this trunk g roup are alarmed.
test port UUCSSpp long DID Trunk
DID-TRK MINOR test port UUCSSpp long DID Trunk
DID-TRK WARNING test port UUCSSpp DID Trunk
Table 1-2. DID Trunk Error Log entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
1537 Port Diagnostic
(#35) MAJ/MIN/
WRN OFF test port UUCSSpp sh r 1
3840 (k) 40965 None
Continued on next page