DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-342BRI-SET, ASAI-ADJ, BRI-DAT
9
Table 9-150. ISDN-BRI CAUSE VALUES
Error
Code Test Result Description/ Recommendation
1 Requested channel is in use b y another station
on the BRI-PORT. (Not applicable for ASAI or
Lucent adjuncts.)
For BRI endpoints:
1. Try to originate a call to or from this port.
2. If the error persists, busy out an d release
the port.
3. If the problem still persists, replace stations
on the port.
4. If the problem still p ersists, escalate to the
next tier.
34 No circuit or
channel
available
A resource on the switch is unavailab le for a
call. For BRI endpoints: This cause value is no t
logged. For ASAI or Lucent Adjunc ts: This
condition means that there are no availab le
trunks for an outgoing call request.
1. Verify that the adjunct is administered to
support the trunk capabilities of the switch.
2. Investigate trunk group status by issuing
status trunk commands from the SAT or by
requesting a trunk group query or queries
from the adjunct.
3. Perform trunk diagnostic procedures
outlined in this manual.
4. If step 3 does not resolve the p roblem,
escalate to the next tier.
42 Switch
Equipment
Congestion
Switch takes control to limit received traffic. For
BRI endpoints: This cause value is not logg ed.
For ASAI or Lucent Adjuncts:
1. See CallVisor protocol reference manual.
2. If step 1 does not resolve the p roblem,
escalate to the next tier.
Continued on next page