DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-686DS1 CONV-BD
9
Table 9-265. TEST #789 Far-end FOT (Lightwave Transceiver) Loopback Test
Error
Code Test
Result Description/ Recommendation
1410 ABORT The test aborted because no lightwave transceiver is present. The neighbor
DS1 CONV circuit pack and the fiber endpoint are connected via metallic
cable. This abort may b e ignored.
2000 ABORT Timed out while waiting for a response from the circuit pack.
2100 ABORT Could not allocate the nec essary system resources to run this test .
2300 ABORT The downlink message necessary to run this test could not be sent.
2301 ABORT The timer could not be set before sending the downlink message necessary to
run this test.
1. Retry the command at 1-minute intervals a maximum of 3 times.
2316 ABORT Fiber link is not administered. Administer the DS1 CONV fiber link via the add
fiber-link command.
2321 ABORT DS1 CONV circuit pack is not busied out. Busyout the DS1 CONV circuit pack
via the busyout board command.
2332 ABORT The test was aborted because it cannot be run at the far-end with this system
configuration (PNC simpl ex) when there is only one DS1-FAC available (the
link wo uld b e lost and no test re sults w ould b e seen at the SPE) . Run the test at
the other end of the DS1C complex.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 3 times.
Continued on next page