DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-258ATM-TRK (Circuit Emulation Service Circuit Pack)
9
Error Log Entries and Test to Clear Values
busyout/release atm
signaling-group Busyout or release of an ATM signaling group within a trunk group.
status atm
signaling-group Show current status of an ATM signaling group.
status trunk-group Shows status of the trunk group (ATM signaling groups are part of
trunk groups).
Table 9-117. ATM-TRK Error Log entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
0 0 Any Any test board UUCSS
1(a) None MIN ON
18(b) 0 busy out board UUCSS MIN ON release b oard UUCSS
23(c) 0 None MIN ON
125(d) None MIN ON
257(e) Any Control Channel Loop
Test (#52) MIN ON test board UUCSS r 2
513(f) Any ATM Cross talk Test
(#1298) MIN ON test board UUCSS l r 1
769(g) 35 ATM Error Query Test
#1259 WRN OFF test board UUCSS
770(g) 25 ATM Error Query Test
#1259 WRN OFF test board UUCSS
771(h) 26 ATM Error Query Test
#1259 WRN OFF test board UUCSS
1281(i) ATM Board Error Query
Test (#1259) WRN/
MIN OFF test board UUCSS r 1
1537(j) 12 None WRN/
MIN ON
1538(k) 0 None WRN/
MIN ON reset board UUCSS
Continued on next page
Table 9-116. ATM CES troubleshooting commands — Continued
Command Description
Continued on next page