9-1459SNI-BD (SNI Circuit Pack)
9
105 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot 5.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER err or type 769, replace the S NI being
tested. Replacing an SNI may be service interrupting. Refer to the SNI-BD
section for the procedure for replacing an SNI. To view SNI-PEER errors,
use the display errors command with category PNC-PEER. Retry the
command.
3. If the SNI being tested has SNI-PEER err or type 769, replace the SNI in slo t
5. Replacing an SNI may be service interrupting. Refer to the SNI-BD
section for the procedure for replacing an SNI. Retry the command.
106 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot 6.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER error type 1025, replace the SNI
being tested. Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure for replacing an SNI. To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
3. If the SNI being tested has SNI-PEER error type 1025, replace the SNI in
slot 6. Replacing an SNI may be service interrupting. Refer to the SNI-BD
section for the procedure for replacing an SNI. Retry the command.
107 FAIL The SNI circuit pack cannot communicate with the equipped SNI in slot 7.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER error type 1281, replace the SNI
being tested. Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure for replacing an SNI. To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
3. If the SNI being tested has SNI-PEER error type 1281, replace the SNI in
slot 7. Replacing an SNI may be service interrupting. Refer to the SNI-BD
section for the procedure for replacing an SNI. Retry the command.
Table 9-562. TEST #759 Configuration Audit — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page