DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-635DS1-BD (DS1 Interface Circuit Pack)
9
0NO
BOARD The test could not relate the internal ID to the port (no board).
This could be due to incorrect translatio n s, no board is inserted , an incorrect
board is inserted , or an insane board is inse rted.
1. Check to ensure that the board translations are correct. Use the add ds1
UUCSS command to admini ster the DS1 interface if it is not alread y
administered.
2. If board was already administered correctly, check the error log to
determine if the board is hyperactive. If this is the case, the board is shut
down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, issue the busyout
board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 9-254. TEST #1227 ICSU Status LEDs Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page