DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Additional Maintenance Procedures
6-45Automatic Transmission Measurement System (ATMS)
6
processing, the test ab orts. When the trunk is already being test ed by
maintenance software, the test is queued and run when the maintenance ac tivity
finishes.
Measurement data gathered b y analog testcalls can b e retrieved with the list
testcalls command which i s described b elow. Which measurements are made
and recorded d epends on which typ e of test is specified an d the capabilities of
the far-end TTL.
Screen 6-1 shows a typical result for test analog-te stcall trunk 60
Screen 6-1. Test Results for test analog-testcall trunk 60
Output Fields
Port The physical location of the port s upporting the trunk
being tested. The format is UUCSSpp where UU is the
cabinet number, C is the c arrier letter, SS is the circuit
pack slot, and p p is the port circuit numb er.
Maintenance
Name The name of the maintenance object tested , TIE-TRK
or CO-TRK.
Alt. Name The trunk group number and member number of the
trunk being tested.
Test Number ATMS tests are numbered 844 through 848.
Result If the test call succe ssfully completes, and all tru nks
test within administered threshold s for marginal and
unacceptab le performance, then a PASS result is
returned. If measurements fall outside the t hresholds,
the test fails. The trunks group can b e administered to
log errors and alarms, and to b usy out the failed trunk.
If the test call cannot be c ompleted, an ABORT is
returned.
test analog-testcall trunk 60 SPE B
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
02B1901 TIE-TRK 060/001 845 PASS
02B1902 TIE-TRK 060/002 845 PASS
02B1903 TIE-TRK 060/003 845 PASS
02B1904 TIE-TRK 060/004 845 ABORT 1004
02B1905 TIE-TRK 060/005 845 PASS
02B1906 TIE-TRK 060/006 845 ABORT 1004