9-23ADX16D-B (16 Port AUDIX Circuit Pack)
9
ADX16D-B (16 Port AUDIX Circuit
Pack)
The ADX16D-BD maintenance object represents a TN566/TN2169 DEFINITY
AUDIX circuit pack combination operating in 16 port mode digital (DP). For
circ uit-p ack- level prob lems, s ee “XXX- BD (Com mon Por t Circ uit Pac k)”.
Port-level maintenance is covered b y ADX16D-PT.
DEFINITY AUDIX consists of 2 circuit packs that occup y 5 slots on a port carrier.
The tests described in this manual apply only to switch-sid e maintenance which
tests circuit pack components related to the TDM bus interfac e. The AUDIX
system has an extensive maintenance strateg y of its own that is described in
DEFINITY AUDIX System Maintenance
, 585-300-110.
MO Name (in
Alarm Log) Alarm
Level Initial Command to Run1
1. UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in whic h the c irc ui t p ac k
resides (01 to 21).
Full Name of MO
ADX16D-B MINOR test board UUCSS sh AUDIX Circuit Pack