DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Commands
8-354test mssnet
8
test mssnet
test mssnet C [short | long][repeat |clear][schedule]
The test mssnet c ommand runs a series of diag nostic tests on the MSSNET
circuit pack. Tests are run on both maintenanc e objects located on the MSSNET
circuit pack: host-ad apter (H-ADAPTR) and switch control (SW-CTL).
Parameters
Output
The following display shows a typ ical result when test mssnet 1a is entered.
CThe cabinet is always 1 and need not be entered. The carrier, a or b, must b e
spec ifie d in a dup lic ated SPE syste m.
clear The clear option does not provid e a useful function for this command . MSSNET
is used only as a command object to run tests of the MSSNET circuit pack.
Failures of circuits on the MSSNET board cause alarms ag ainst H-ADAPTR and
SW-CTL. Individual demand tests of those maintenance ob jects should be used
to clear associated alarm s.
test mssnet 1a SPE A
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01A H-ADAPTR 822 PASS
01A H-ADAPTR 823 PASS
01A H-ADAPTR 824 PASS
01A H-ADAPTR 825 PASS
01A SW-CTL 92 PASS
Command Successfully Completed