Maintenance Object Repair Procedures
9-1252PKT-INT (Packet Interface Circuit Pack)
9
1025, (m) Any Private Looparound
Test (#885) MAJOR2ON reset packet-interface CS3
1026 Any None MAJOR2ON reset packet-interface CS3
1281 (n) Any None MAJOR2ON reset packet-interface CS3
1537 (o) Any Memory Checksum
Test (884) MINOR ON test packet-interface CS l r
2
1793 (p) Any Memory Checksum
Test (#884) MINOR ON test packet-interface CS l r
2
2049 (q) Any None WARNING ON test packet-interface CS r
25
2305 (r) Any None test packet-interface CS r 2
2561 (s) Any Active-Standby Peer
Link Test (#888) MINOR OFF test packet-interface CS s r
2
2817 (t) Any Read and Clear Test
(#887) MINOR/
MAJOR2ON test packet-interface CS s
3074,
3073,
3072 (u)
Any Maintenance
Looparound Test
(#886)
WARNING OFF test packet-interface CS s r
2
3329 (v) Any None WARNING OFF reset packet-int e rface CS3
3585 (w) Any None WARNING OFF reset pac ket-interface CS3
3841 (x) Any None MAJOR2OFF reset packet-interfac e CS3
1. Indicates that an alarm was raised but an associated error was not entered into the hardware error
log due to a momentary overload condition caused b y a burst of hardware or software error reports.
Run the long test sequence. Refer to the appropriate test descriptions for any failures and follow the
recommended procedures.
2. If a spontaneous interchange has occurred (as indicated by STBY-SP E error type 103 or the display
initcauses screen), and handshak e is d own, (check with status spe), replac e the alarmed c ircuit
pack on the standby SPE. If handshake is up, execute a test long clear of the alarmed circ uit pack
and follow recommend ed proced ures.
3. A Packet Interface cir cuit pack on an ac tive SPE can only be reset if it has been taken out of service
by background maintenance software. A Packet Interface circuit p ack on a standb y SPE can be
reset independent of its service state.
Table 9-497. Packet Interface Error Log Entries — Continued
Error
Type Aux
Data Associated Test Alarm Level On/Off
Board Test to Clear Value