DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1040MET-LINE (MET Line)
9
Error Log Entries and Test to Clear Values
Notes:
a. The data link between the port and the term inal is not operational, i.e., the
port circuitry has detected an off-boa rd problem. Verify that the MET set is
connected and that the Electronic Power Feed (EPF) test passes. If data
transmission problems are experienc ed, check for defective wiring or a
defective voice ter minal, or move terminal electric ally closer to the switch
(i.e., reduce the length of the wiring b etween the terminal and the switch).
If the problem persists, rep lace the circuit p ack. Once the prob lem is
resolved, the system retires the alarm after a pred etermined time delay.
Table 9-411. MET Line Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test Se quence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended proc edures.
0 Any Any Any test port UUCSSpp sh r 1
1 (a) 40987 None
18 (b) 0 busyout port
UUCSSpp WARNING OFF releas e po rt UUC SSpp
130 (c) None WARNING ON test port UUCSSpp sh
257 (d) 40988 None MIN/WRN2
2. Major or Minor alarms MO may be downgraded to Warning alarms based on the values used in the set
options command.
OFF
513 (e) 40965 Hybrid Line Station
Audits Test (#61) WARNING OFF test p ort UUCSSpp sh r 4
769 Port Diagnostic Test
(#35) MIN/WRN2ON test port UUCSSpp l r 3
1025 Hybrid & Conf.
Circuits Test (#57) MIN/WRN2ON test port UUCSSpp l r 3
1537 (f) 40968 None MIN/WRN2OFF
1793 TDM NPE Crosstalk
Test (#6 MIN/WRN2ON test port UUCSSpp l r 3
2049 (g) 32770
2049 (h) 40967
3840 (i) 40989