DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-349BRI-SET, ASAI-ADJ, BRI-DAT
9
Table 9-152. TEST #627 BRI Remote Loop Back
Error
Code Test
Result Description/ Recommendation
1000 ABORT Could not seize the endpoint or B-channels for test.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1005 ABORT The endpoint’s MIMs Supported field is administered to ‘‘ no.’’
1. Use the change station extension command to change parameter only
if the endpoint documentation reflects support for ISDN-BRI
Management and Maintenance Procedures.
1113 ABORT The signaling link between the switch and the endpoint is down.
1. Use the test port PCSSpp long command to c lear any errors which
prevent establishment of t he signaling link.
2. Examine the results of the Signaling Link Status Test (#626) which is run
as part of this command. If this test aborts or fails, follow the repair
procedure for Test #626.
3. If the XID Test #628 continues to abort, escalate the problem.
1139 ABORT The Packet Bus in the port network is out-of-service.
1. Follow the repair procedures for the Packet Bus.
2. After completi ng Step 1, execute the test port long PCSSpp command,
and review the results of the BRI Port Local LAN Loop Around Test to
verify the repair.
1141 ABORT The PKT-CTRL is out-of-service.
1. Refer to PKT-CTRL (Packet Control Circuit Pack) Maintenance
documentation.
2. If Step 1 does not resolve the problem, escalate to the next tier.
1144 ABORT The PPN Packet Bus is out-of-service.
1. Follow the repair procedures for the Packet Bus in the PPN.
2. After completi ng Step 1, execute the test port long PCSSpp command,
and review the results of the BRI Port Local LAN Loop Around Test to
verify the repair.
Continued on next page