DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1947XXX-BD (Common Port Circuit Pack)

9
Ringing Application Test (#51)

This test checks the ringing application c ircuitry common to all p orts on an

Analog Line circuit p ack.

Table 9-722. TEST #51 Ringing Application Circuit Test
Error
Code Test
Result Description/ Recommendation
1000
2100 ABORT Could not allocate the necessary system resources to run test.
ABORT Could not allocate the necessary system resources to run test. The circuit
pack is not installed. Internal system error
2000 ABORT There was no response from the board.
1. If error type 1538 (hyperactivity) is present in the error log, follow the
maintenance strategy that is recommended for this error type.
2. Run the busyout board, reset board, and release busy board
commands,and then retest.
3. If the test still aborts, dispatch with the circuit p ack.
4. Check the off-board wiring and the terminal, and, if there are no problems
found, replace the circuit pack.
1004 ABORT The port was seized b y a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the station
extension. Use the status station command to determine the service
state of the port. If the service state indicates that the port is in use, then
the port is unavailable for certain tests. (Refer to Chapter 8, for a full
description of all possible states). You must wait until the por t is idle
before retesting.
2. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page