Maintenance Object Repair Procedures
9-1019MAPD-BD (MAPD Interface Circuit Pack TN802)
9
Control Channel Looparound Test (#52)
This test queries the circuit p ack for its circuit p ack code and vintage and verifies
its records.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS The circuit pack’s SCOTCH-NPE chip has been updated with its translation.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane bo ard is inserted.
1. Ensure that the board translations are correct. Execute the add ds1
UUCSS command to administer the MAPD interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board
is shut down. Reseating the b oard re-initializes the board .
3. If the board was found to be correctly inserted in Step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.
Table 9-394. TEST #52 Control Channel Looparound Test
Error
Code Test
Result Description/ Recommendation
None
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 9-393. TEST #50 NPE Connection Audit Test — Continued
Error
Code Test
Result Description/ Recommendation