DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-150ATM-BCH (ATM B-Channel Trunk)
9
Table 9-62. ATM-BCH alarms by service state
Service state Alarm1
1. ATM-BCH alarms; alarms against other maintenance objects may also be present.
Possible cause Possible solution
Out-of-Service/NE
Warning Trunk busied out Release the port (release trunk
grp#
/
mbr#
).
Minor NPE Crosstalk Test (#6 )
failed Replace ATM circuit pack.
None ATM circuit pack lost
signal or there is a
circuit pac k problem.
Install circuit pack or cable. Check
circuit pack using proc edures in
ATM-BCH. Check far-end switch
status.
Out-of-Service/FE
Warning Unadministered far-end Ad minister the corresponding trunk
on the far-end switch.
Warning Far-end busied out Check the status of the far-end
switch.
Pending/In-Service
Pendin g/Mai nt None Maintenance message
timed out waiting for
reply
Wait 2 minutes after the pending
state clears, and ch eck the service
state.
Maint/NE
None ISDN test call in
progress (test trunk
long)
Wait for the test to finish and
recheck.
None System link busied out Check link status. Run release link
link#
.
Maint/FE
Warning Signaling channel
down for over 90 sec. See ATM -SGRP or ATM-DCH.
Warning Repeated lack of
response to messages
sent to the far end
Wait. Maintenance software resends
messages periodically. Or run test
trunk
grp#
/
mb#
or test
signaling-grp
grp#
.
Warning The far-end trunk is
being tested. Check status of the far-end switch.
Wait for testing to finish.
In-Service None Normal operating state
Continued on next page