DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-170ATM-EI (Expansion Interface Circuit Pack)
9
A-side ATM PNC EI — Critical Reliability
1. Remove the ATM PNC connection (see ‘‘Removing ATM PNC
connections’’ above).
2. Add an ATM PNC connection (see ‘‘Adding ATM PNC connections’’
above).
B-side ATM PNC EI — Critical Reliability
1. Enter status pnc and ensure that the A-PNC is active.
If it is not active, request a pnc interchange using the reset pnc
interchange command.
2. Enter busyout pnc-standby.
3. Enter list config car and verify that an ATM circuit pack is administered
for the new location. If it is not, add the ATM circuit pack translations.
4. Enter busyout atm pnc
n
(connection number) b-pnc.
5. Enter change atm pnc
n
(connection number) and change ci rcuit pack
location for the B side.
6. Enter release pnc-standby.
Changing ATM address of a B-side ATM-PNC EI — Critical Reliability
1. Enter busy pnc-standby.
2. Enter change atm pnc
n
(connection number) and change the ATM
address for the B side.
3. Enter release pnc-standby.
Error Log Entries and Test to Clear Values
Table 9-74. ATM-EI Error Log Entries
Error
Type Aux
Data1Associated Test Alarm
Level On/Off
Board Test to Clear Value
020 Any Any Any test board UUCSS
2 (a) None MIN ON
18 (b) 0 busy out board UUCSS WAR OFF release board UUCSS
23 (c) 0 None WA R OFF
125 (d) None MIN ON
131 (e) None MIN ON
Continued on next page