Maintenance Object Repair Procedures
9-477DID-DS1 (Direct Inward Dial Trunk)
9
1001 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of- service due to TDM
BUS error. Use status health to determine if the system is experiencing heavy
traffic.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present or some tone detectors may
be out-of-service. Use list measurements tone-receiver to display information
on the tone receivers.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals a
maximum of 5 times.
1004 ABORT The port was seized by a user for a valid call.
1. Use display port UUCSSpp to determine the trunk group/member number
of the port. Use status trunk to determine the service state of the port. If
the port is in use, wait until th e port is idle before testing .
2. If the port status is id le, retry the command at 1-minute i ntervals a
maximum of 5 times.
1020 ABORT The test did not run due to a previously existing error on the specific port or a
more general circuit pack error.
1. Examine Error Log for existing errors against this port or circuit pack and
attempt to diagnose the previously existing error.
2000 ABORT Response to the test was not received within the allowable time period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2053 ABORT At least one of the following errors is found on the DS1 circuit pack (DS1-BD or
UDS1-BD): 1281Loss of signal, 1793Blue Alarm, 2049Red Alarm,
2305Yellow Alarm, or 1537Hyperactivity
1. Resolve any of the above error types.