1004 ABORT The port was seized by a valid call during the test.
1. Enter display port UUCSSpp to determine the station extension, attendant
number, or trunk group/member number of the port. Use the status
station, status attendant, or status trunk command to determine the
service state of the port. If the port is in use, wait until the port is idle before
testing. Attendants are always in use (off-hook) if the handset is plugged in
and the port is not busied out.
2. Retry the command at 1-minute intervals a maximum of 5 times.
1018 ABORT Test disabled via administration. Verify that the Maintenance Tests? field on
the Trunk Group Form is set to n. To enable the test, issue the change
trunk-group x command (x is the trunk group number). Then change the entry
in the Maintenance Tests? field to y.
2000 ABORT Response to the test was not received within the allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
61446 FAIL Battery feed test failed. A loop current fault was detected. This is most probably
an incoming CO-line problem. This failure code is only reported by the TN2139
Italian DID circuit pack.
1. Check the incoming CO-line for loop current. If none is detected refer the
problem to the CO.
2. If the CO-line checks out OK, the failure must be on the DID port. Replace
the circuit pack.
61456 FAIL Battery feed test failed. An on-board problem was detected . This port is
out-of-service.
1. Replace c ircuit pack.
61472 FAIL Battery feed test failed. A problem with the incoming CO-line was detected.
1. Check the inc oming CO-line for prop er operation. If warranted , refer the
problem to the CO.
2. If the CO-line is not at fault, the failure must be on the DID port. Replace the
circuit pack.
PASS Current flow was detected for this port.
1. User-reporte d troubles on this p ort should be invest igated using oth er port
tests and by examining connections.
2. Refer problem to the CO.
Table 9-202. TEST #35 Port Diagnostic Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page