DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-492DID-TRK (Direct Inward Dial Trunk)

9
Port Diagnostic Test (#35)

This test checks a port’s b attery feed circuitry fo r on-/off-hook detection, battery

shutdown, and battery reversal (wink) capabilities.

0NO
BOARD The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should establish the link between
the internal ID and the port.
Table 9-202. TEST #35 Port Diagnostic Test
Error
Code Test
Result Description/ Recommendation
ABORT System resources required to run this test were not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test were not available. The port may be
busy with a valid call.
1. Enter display port UUCSSpp to determine the trunk group/member
number of the port. Use the status trunk command to determine the
service state of the port. If the port is in use, wait until the port is idle before
testing.
2. If the port stat us is active but the p o rt is not in use (no calls), c heck the
error log for Error Type 513. The port may be locked up.
3. If the port status is idle, busyout and release the trunk, and retry the
command at 1-minute intervals a maximum of 5 times.
4. If the test continues to abort, check for wiring errors toward the CO which
may cause the trunk to lock up.
5. If the wiring is good and the test continues to abort, replac e the TN753.
Continued on next page
Table 9-201. TEST #33 Looparound and Conference Circuit Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page