TCP/IP Ping Test (#1281)

This non-destructive test fails if the endp oint fails to respond. Use this test to

check the circuitr y in the data path for a peer-to-p eer IP layer connection.

2000 ABORT Did not receive circuit pack test response within the allowable time period .
1. If this problem persists, reset the circuit pack (busyout board UUCSS
and reset board UUCSS).
2. If the problem persists, replace the circuit p ack.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2100 ABORT Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals, up to 5 times.
FAIL CLAN circuit pack detec ted test failure.
1. If the problem persists, reset the circuit pack ( busyout board UUCSS
and reset board UUCSS).
2. If the problem persists, replace the circuit p ack.
PASS Port circuitry functioning properly.
Table 9-520. TEST #1281 TCP/IP Ping Test
Error
Code Test
Result Description/ Recommendation
1, 2 ABORT Internal error
1. Retry the command at 1-minute intervals a maximum of 3 times
7 ABORT Destination unreachable.
1. Verify that at least one destination reachable through this port is up.
Once verified, test the port again (test port UUCSS) verify that the
TCP/IP Ping Test (#1281) passes.
Continued on next page
Table 9-519. TEST #1275 SCOTCH Synchronous Looparound Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page