DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-113ANN-PT (Announcement Port)
9
ANN-PT (Announcement Port)
There are 16 announcement ports on the announce ment circuit pac k. Each port
can play any integrated announcement, indep endently of the other ports. In
addition to the 16 por ts, the announcement circuit p ack also has one data line
circuit port (Port 17). The data line c ircuit port is used f or uploading/d ownloading
the announcement memory to/from the system tape or disk devices. If there are
any errors associated with Port 17, refer to DAT-LINE maintenance information. If
there are any errors associated with the circ uit pack, refer to “ANN-BD
maintenance information.

Essential Service Information

There are a number of important basic principles that shoul d be understood
before undertaking work on the announc ement circuit pac k. These are described
in

Essential Service Information

at the beginning of the “ ANN-BD“ section of this
chapter.
Although announcement por t 5 and data line circ uit port 17 on the
announcement circuit p ack are logically two sep arate ports, they are physi cally
the same port. Therefore, if one of the ports is in use, the oth er one will be busy.
Also, if announcement port 5 is out-of-s ervice, the data line circ uit port will be
taken out-of-service. However, if the data li ne circuit port is out-of-ser vice, the
announcement port will remain in-servic e.
MO Name (in
Alarm Log) Alarm
Level Initial Command to Run1
1. UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs), C is the carrier
designation (A, B, C, D, or E), and SS is the number of the slot in which the circuit
pack resides (01 to 21). pp is the two digit p ort number (01, 02, ...).
Full Name of MO
ANN-PT MINOR test port UUCSSpp l Announcement Port
ANN-PT WARNING test port UUCSSpp l Announcement Port