DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1380SN-CONF (Switch Node Configuration)
9
FAIL If this test fails, not all of the administered circuit packs in this switch node
carrier responded with an up-link board insertion message. Check to see that
administered SNI and SNC boards match the physically installed SNI and SNC
boards by entering list config carrier UUC. The command output will show
"NO BOARD" for every board that is administered , but not inserted.
If all administered b oards are inserted, run this test ag ain.
If administration does not match the physical c onfiguration, and is
correct
,
insert the missing circuit packs in this switch node carrier.
If administration does not match the physical configuration, and is
incorrect
, change the administration and run this test again.
If
none
of the administered boards in this switch node carrier were
inserted, fix any other SN-CONF errors by following the associated repair
procedures for SN- CONF. Use display errors with category pnc to view
SN-CONF errors. Next check if any INLs, LNLs, or R N L s a re down with list
sys-link. If any INLs, LN Ls, or RN Ls are d own, ref er to th e SYS-LINK
section for fixing link problems.
PASS If this test passes, all of the administered circuit packs in this switch node
carrier were inserted.
Table 9-548. TEST #760 Processor Route Audit Test — Continued
Error
Code Test
Result Description/ Recommendation
Continued on next page