DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-475DID-DS1 (Direct Inward Dial Trunk)
9
Maintenance does not start any testing or generate any alarms in
response to these errors.
b. Error Type 15This is a software audit error that does not indicate any
hardware malfunction. Run Short Test Sequence and investigate errors (if
any).
c. Error Type 18The trunk has been taken out of servic e by a demand
busyout. No calls can b e made on this trunk.
d. Error Type 130This error type indicates that the circuit pack has b een
removed or has been insane for more than 11 minutes. To clear the error,
reinsert or rep lace the c ircuit pac k.
e. Error Type 257DS1 Interface circuit p ack detects a hardware error on
the DS1 DID trunk. The Aux Data field indicate the source of the er ror:
f. Error Type 513DS1 Interface circuit p ack detects a hardwa re error on
the DS1 DID trunk. Aux Data 57392 indicates no external release o n PBX
disconnect.
g. Error Type 769DS1 Interface circ uit pack detects a hard ware error on
the DS1 DID trunk. Aux Data 57393 indicates belated external release on
PBX disconnect.
h. Error Type 1793DS1 Interface circuit pac k is out-of-service. Look for
DS1-BD/UDS1-BD errors in Hardware Error Log. Refer to the appropriate
“DS1-BD/UDS1-BD” information for details.
i. Error Type 2305—This error indicates that a signaling c hange was
detected by the PBX trunk circuit pack which is inc onsistent with the
present state of the trunk.
j. Error Type 3840Port Audit and Update Test (#36) failed due to an
internal system error. Enter status trunk command to verify the status of
the trunk. If the trunk is out-of-service, then enter the release trunk
command to put it b ack to in-service. Retry the test command.
57474 Rotary dial rate above 12 pulses p er second
57473 Rotary dial rate below 8 pulses p er second