DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1327PPP-PT (Control LAN Packet/Port)
9
2. Refer to SCOTCH Synchronous Looparound Test (#1275) repair
procedures to verify repair .
3. Clear the alarm (test port UUCSSpp long clear).
c. Error Type 513: PPP link lost e nd-t o-en d co nnec tivi ty.
1. Test for hardware problem (test port UUCSSpp long).
2. Run TDM Looparound Test (#1285) and refer to repair procedures if
there is a hardware problem.
If the re is n o hard ware prob lem , the s witc h tri es to re-es tabl ish PPP
link.
d. Error Type 769: Port received an invalid frame, whic h
is greater than the maximum length
contains CRC errors
violates the link level protocol.
1. Test the port (test port UUCSSpp long).
2. Refer to TDM Port Looparound Test (#1285) to verify repair.
3. Clear the alarm (test port UUCSSpp long clear).
e. Error Type 1281: System software received an indication that the far-end
has requested a disc onnect of a session on this link. This is a log-only
error.
f. Error Type 1537, 1538: Some or all port sessions (sockets) are down.
g. Error Type 1793-1920: system software received an indic ation that a
socket was closed d ue to an error. Error Type indicates the applic ation f
the application assoc iated with this socket.
Aux Data indicates the interna l application numb er.
h. Error Type 2305-2816: System software detected a session is d own. Aux
Data indicates the session numb er.
If the switch indicates that: Then it:
Some of the sessions are down Raises off-board WARNING
All of the sessions are down Raises off-board MINOR alarm
Error Type Application
1794 DCS
1795 AUDIX
1796 CMS
1797 ISDN Gateway