DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-14ADX8D-BD (AUDIX Circuit Pack)
9
ADX8D-BD (AUDIX Circuit Pack)
The ADX8D-BD maintenance object represents a TN566/TN2169 DEFINITY
AUDIX circuit pack (sometimes c alled Embedded AUDIX) operating in
dig ital-p ort ( DP) mod e. For circ uit-p ack- level prob lems, see ‘‘XXX- BD (Com mon
Port Circuit Pack)’’. Port-level problems are covered by ADX8D-PT.
DEFINITY AUDIX consists of two circuit packs that occup y 5 slots on a port
carrier. The tests describ ed in this manual apply only t o switch-side maintenance
which tests circuit p ack components related to the TDM bus interface. The
AUDIX system has an extensive maintenance strategy that is d escribed in
DEFINITY AUDIX System Maintenance
, 585-300-110.
MO Name (in
Alarm Log) Alarm Level Initial Command to Run1
1. UU is the universal cabine t number (1 for PPN, 2 - 44 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21).
Full Name of MO
ADX8D-BD MINOR or
WARNING test board UUCSS sh AUDIX Circuit Pack