DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-8AC-POWER
9
AC-POWER for DC-Powered Systems
NOTE:
In a DC-powered Multi-Carrier Cabin et, the AC-POWER maintenance
object exists, but serves no functional purpose. Bec ause the system cannot
determine the type of p ower used, the AC-POWER test should always pass
or abort. The maintenance strategy for p ower components in DC c abinets
is described in the ‘‘CARR-POW (Carrier Power Supply)’’ section.
DEFINITY supports two different cabinet types: Multi-Carrier Cabinets and
Single-Carrier Cabinets. Single-Carrier Cabi nets are used only for EPNs. Both
cabinet types may b e powered by either AC o r DC power source. Environmental
maintenance differs acc ording to cab inet type and external p ower supply.
Error Log Entries and Test to Clear Values
MO Name (in
Alarm Log) Alarm
Level Initial Command to Run Full Name of MO
AC-POWER WARNING test environment UU1
1. UU is the universal cabine t number (1 for PPN, 2 - 44 for EPNs).
AC Power
Table 9-3. AC Power Error Log Entries
Error
Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
01
1. Run the Short Test S equence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended proc edures.
0 Any Any Any test environment UU sh r 1
513 Any AC Power Query
Test (#78) WARNING OFF test environment UU sh r 1