DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures

9-1164PDMODULE (Processor Data Module) TDMODULE (Trunk Data Module)

9
Error Log Entries and Test to Clear Values
Notes:
a. Error type 0 appears in the Error Log only if a Dig ital Line circuit pac k that has ports administered has been removed since the Error Log was last cleared. Make sure that the circ uit pack has been re-inse rted.
Table 9-463. PDMODULE, TDMODULE Error Log Entries
Error Type Aux
Data Associated Test Alarm
Level On/Off
Board Test to Clear Value
0(a) 0 None
1(b,n) 40987 None WARNING OFF
1(c,n) 1 to 20 None WARNING OFF
15(d) Any None
18(e) 0 busyout port
UUCSSpp
WARNING OFF release port
UUCSSpp
257(f) 40971 None
513 0 Data Module Audits
(#17) WARNING OFF test port
UUCSSpp
sh r 6
769(g,n) 40988 None WARNING OFF
1281 Any Data Module Audits
(#17) WARNING OFF test port
UUCSSpp
sh r 4
1537(h,n) 40968 None WARNING OFF
1793 Information Channel
and Control Channel
Looparound (#13)
MINOR ON test port
UUCSSpp
l r 3
2049 NPE Crosstalk (#9) MINOR ON test port
UUCSSpp
l r 3
2304(i) None
2305(j) 32770 None
2305(k) 40967 None
2561(l) Any Data Module Internal
Looparound (#175) WARNING OFF test port
UUCSSpp
l r 5
2817 (m) Link GPP Loop (183)
Against Links MAJOR ON
3841 n) NONE
3841(o) None