DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-476DID-DS1 (Direct Inward Dial Trunk)
9
System Technician-Demanded T ests: Descripti ons
and Error Codes
Always investigate tests in the order they are p resented in the table below. By
clearing error cod es associated with the
NPE Crosstalk Test,
for example, you
may also clear errors generated from o ther tests in the testing sequence.
NPE Crosstalk Test (#6)
The NPE Crosstalk Test verifies that this port’s NPE channel talks on the se lected
time slot and never crosses over to time slots rese rved for other connections. If
the NPE is not working correctly, one-way and noisy connec tions may be
observed. This test is usually only pa rt of a port’s Long Test Sequence and takes
about 20 to 30 seconds to c omplete.
Order of Investigation Short Test
Sequence Long Test
Sequence D/ND1
1. D = Destructive; ND = Nondestruc tive
NPE Crosstalk Test (#6) X ND
Conference Circuit Test (#7) X ND
Port Audit and Update Test (#36) X X ND
Table 9-196. TEST #6 NPE Crosstalk Test
Error
Code Test
Result Description/ Recommendation
ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required for this test are not available.
The port may be busy with a valid call.
1. Use display port UUCSSpp to determine the trunk group/ member
number of the port. Use the status trunk command to determine the
service state of the por t. If the port is in use, wait until the p ort is idle before
testing.
2. If the port status is active but the port is not in use (no calls), chec k the
error log for error type 1025. The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals a
maximum of 5 times.