DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-396CLAN-BD (Control LAN Circuit Pack)
9
Control Channel Loop-Around Test (#52)
This non-destructive test fails if the circ uit pack does not return to a sane state
after being reset. This test queries the ci rcuit pack for its cod e and vintage, and
verifies its records.
Circuit Pack Restart Test (#252)
This test is destructive.
Execute this test (not part of either short or long demand test sequenc e) to reset
the circuit pac k, only if there are PPCPU errors. This test fails if the circuit pack
does not return to a sane state after being reset. The circuit pack resets throug h
the SAKI Sanity Test (#53).
Table 9-163. TEST #52 Control Channel Loop-Around Test
Error
Code Test
Result Description/ Recommendation
None
2100 ABORT Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals, up to 5 times.
FAIL The circuit pack failed to return the code or vintage.
1. Retry command at 1-minute intervals, up to 5 times.
2. a. If the test continues to fail with a Port circuit pack, reseat the circuit
pack; otherwise,
b. If the tes t cont inues to fail on SPE Proc essor C omple x circ uit p acks ,
refer to
Replacing SPE Circuit Packs
in Chapter 5 (Responding to
Alarms and Errors) to remove and reinsert the circuit pack.
PASS Test successful.
Table 9-164. Test #252 Circuit Pack Restart Test
Error
Code Test
Result Description/ Recommendation
None ABORT Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals, up to 5 times.
1015 ABORT Port is not out-of-service.
1. Busyout the circuit pack (busyout board UUCSS).
2. Retry the command at 1-minute intervals, up to 5 times.
2100 ABORT Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals, up to 5 times.
Continued on next page