DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-734DUPINT (Duplication Interface Circuit Pack)
9
b. A local DUPINT FIFO overflow condition has been reporte d. If this alarm
cannot be cleared by replacing th e active Duplication Inter face circuit
pack, escalate the p roblem.
c. In-line errors have been reported from the DUPINT driver. If this alarm
cannot be cleared by replacing th e active Duplication Inter face circuit
pack, escalate the p roblem.
System Technician-Demanded T ests: Descripti ons
and Error Codes
Always investigate tests in the order p resented in the table b elow. By clearing
error codes associated with the
Control Register Test
for example, you may also
clear errors generated from other tests in the testing sequence.
51 The Active DUPINT Reset Test failed because the HFAIL bit stayed set
after reset.
52 The Active DUPINT Reset Test failed because th e state of health could
not be restored after the reset.
55 The Active DUPINT Reset Test failed becau se shadowing co uld not be
turned off after the board was successfully reset.
Aux
Data Cause of Error
23 DUPINT driver suicide
24 DUPINT driver loss of interrupt path
27 DUPINT driver no handshake path for processes
28 DUPINT driver no handshake path for drivers
29 DUPINT driver no control path
30 DUPINT driver main receive failed
Aux
Data Cause of Error