DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-74ANL-24-L (24-Port Analog Line)
9
Table 9-32. TEST #161 Looparound Test
Error
Code Test
Result Description/Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the station
extension.
2. Use the status station command to d etermine the service state of t he
port.
3. If the port is in use, wait until the port is idle and retry the command at
1-minute intervals for a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, retry
the command at 1-minute intervals for a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present or some tone
detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT err o rs.
3. If neither condition exists, retry the command at 1-minute intervals for a
maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted.
1. Use the display port UUCSSpp command to determine the station
extension.
2. Use the status station command to d etermine the service state of t he
port.
3. If the port is in use, wait until the port is idle and retry the command at
1-minute intervals for a maximum of 5 times.
1005 ABORT This test is not run on ports administered as External Alert, Announcement
or combined modem pool ports. This error can be ig nored.
1018 ABORT The test has been disabled by administration. The default for the Test field
on the station form is y. Determine why this field has been set to n on this
station (this may be due to the ringing application test 48, that can be
customer or terminal disturbing).
1. To enable the test for a particular station being tested, enter change
station extension and set the Test? field on the station from n to y.
Continued on next page