9-1841UDS1-BD (UDS1 Interface Circuit Pack)

9
SAKI Sanity Test (#53)
This test is destructive.
This test resets the circuit pack. The test is hig hly destructive and c an only be initiated by a system tech nician-demanded reset boar d UUCSS command.
Table 9-684. TEST #52 Control Channel Looparound Test
Error
Code Test
Result Description/ Recommendation
None
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The circuit pack failed to return the circuit pack c ode or vintage.
1. Retry the command a maximum of 5 times.
2. If the problem continues, and if the circuit pac k is one of the Port circuit
packs, replace the circuit pac k. Otherwise, if the circuit pack is part of the
SPE, use th e proc edure desc ribed in

Replac ing SPE C ircui t Packs

in
Chapter 5.
3. Retry the command a few times a maximum of 5 times.
PASS Communication with this circuit pack is successful.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane b oard is inserted.
1. Ensure that the board translations are correct. Execute the add ds1
UUCSS command to administer the UDS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board
is shut down. Reseating the board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.