DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-678DS1 CONV-BD
9
2. Enter display errors and follow the associated repair p rocedures
for any DS1-FAC errors.
3. If the problem persists, rep lace the DS1 CONV circuit pack.
l. This error only applies to TN574 DS1 CONV circuit pac ks.
If the alarm is on board, then a minor hard ware problem has occ urred that
affects only circuit d ata being transmitted from the DS1 CONV circuit
pack. Replace the DS1 CONV circuit p ack.
If the alarm is off board, then either a minor hard ware problem has
occurred that affects on ly circuit data being transmitted from the DS1
CONV circuit pack or a g ood clock signal c annot be recovered from the
fiber channel.
1. Enter display errors and follow the associated repair p rocedures
for any SYNC, TDM-CLK, and SNC-BD errors.
2. Enter display errors and follow the associated repair p rocedures
for any EXP-INTF, SNI-BD, and FIBER-LK errors.
3. If the problem persists, rep lace the DS1 CONV circuit pack.
m.
This error only applies to TN574 DS1 CONV circuit pack s
.
If the alarm is on board, then a minor hard ware problem has occ urred that
affects only packet d ata being received from the DS1 CONV circuit p ack.
Replace the DS1 CONV circuit pac k.
If the alarm is off board, then either a minor hard ware problem has
occurred that affects only packet data being received from the DS1 CONV
circuit pack or corrupted pac kets are being received from the p acket
facility.
1. Enter display errors and follow the associated repair p rocedures
for any EXP-INTF, SNI-BD, and DS1-FAC errors.
2. If the problem persists enter display errors and follow the
associated repair p rocedures for any SYNC, TDM-CLK, and
SNC-BD errors.
3. If the problem still pers ists, replace the DS1 CONV circuit pac k.
n. If the alarm is on board, then a minor FOI transmit error oc curred that
affects data transmitted from the fib er link to the DS1 facility. Replace the
DS1 CONV circuit pack.
If the alarm is off board, then either a minor FOI transmit error oc curred
that affects data transmitted from the fib er link to the DS1 facility. or
corrupted pac kets are being received from the p acket facility.
1. Enter display errors and follow the associated repair p rocedures
for any EXP-INTF, SNI-BD, and DS1-FAC errors.
2. If the problem persists enter display errors and follow the
associated repair p rocedures for any SYNC, TDM-CLK, and
SNC-BD errors.