DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
555-230-126 Issue 4
June 1999
Maintenance Object Repair Procedures
9-1114M/T-DIG (Maintenance/Test Digital Port)
9
Table 9-442. TEST #13 Digital Port Loop Around Test
Error
Code Test
Result Description/ Recommendation
ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1000 ABORT The port is use on a valid ISDN-PRI Test Call. Use the list isdn-testcall
command to determine which call is using the port (from the M/T Port
column). Either wait for the test call to complete (as indicated in the Start
Time and Duration fields in the above display), or abort the test call with the
clear isdn-testcall grp/mem comm and, where grp/m em is determined from
the B-channel field of the above display.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort and the port is not in use, escalate the
problem.
1001 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions, or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present, or some tone
detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT err o rs.
3. If neither condition exists, retry the command at 1-minute intervals a
maximum of 5 times.
4. If the test continues to abort, escalate the problem.
Continued on next page